SRS and SIL verification digitalization
One connected record for every safety instrumented function.
Safety requirements specifications, SIL calculations and device data usually live in separate documents and spreadsheets, often from different contractors. Keeping them consistent through modifications and proof tests is slow and error-prone. We bring them together in SIFintegrity, so each SIF has one record from its LOPA requirement to its verified design.
Why digitalize your SRS and SIL verification?
- Each SIF links its LOPA requirement, its SRS and its verified design in one place.
- SRS documents and datasheets are issued from the data, so they never drift from it.
- Changes to devices, voting or proof-test intervals show their effect on the SIL straight away.
- Registers of SIFs and equipment you can export at any time for audits and maintenance planning.
What we can work from
- SRS documents in PDF or Word
- SIL verification reports and calculation spreadsheets
- SIF lists, instrument indexes and equipment data in Excel or CSV
- Vendor safety manuals and certificates for failure data
Not sure your records are complete enough? That’s what the free sample is for.
Five steps, with a fixed price agreed after the sample
- 1
Free sample and fixed quote
Send us a real example. We convert up to three SRS and SIF datasheets, linked to a LOPA record if you have one, walk you through the result and quote a fixed price per SIF for the rest.
- 2
Build the registers
We create your SIF register and equipment register, and the structure of each SIF: subsystems, voting and devices. Where your LOPA is digitalized too, each SIF is linked to the scenario that set its requirement.
- 3
Enter the SRS
We enter each SIF’s safety requirements and issue SRS documents and datasheets from the system.
- 4
Verify or record
We either recalculate SIL verification (PFDavg or PFH to IEC 61508-6, architectural constraints by Route 1H or 2H, systematic capability and maximum proof-test interval), or record your existing verification results as they stand.
- 5
Report the gaps
You get a list of SIFs that miss their target, missing device data, and proof-test intervals that don’t support the claimed SIL.
Deliverables
SIF and equipment registers
Every SIF with its structure, devices and an as-built view, in your SIFintegrity deployment.
Issued SRS and datasheets
SRS documents, SRS datasheets and verification datasheets generated from the data.
SIL verification
Recalculated results, or your existing results recorded with their source, backed by a reliability library built from your data and vendor certificates.
Gap report and exports
SIFs that fall short and why, plus register exports in CSV and Excel.
If you buy SIFintegrity
This only applies if you buy a SIFintegrity licence.
The work is then delivered into your own SIFintegrity deployment, so your data stays yours and your team can keep it up to date. We’ll recommend the licence that fits how you’ll use it. We do the bulk loading and archive import for you, so you don’t need a higher tier just for the migration.
Every action, including ours, is written to the audit record.
Not included
- Cause and effect matrices and proof test procedures. These are not part of SIFintegrity today.
- Redesigning SIFs that fall short. We report them; design changes can be quoted separately.
Pair it with LOPA study digitalization to link each SIF to the scenario that set its requirement.
Start with a free sample
Send us a real example: we’ll convert up to three SRS and SIF datasheets, linked to a LOPA record if you have one. We’ll show you the result and quote a fixed price for the rest.